- Measurement of level, distance, volume, difference and flow
- Alarm output in case of flooded sensor possible
- Pump control saves energy and costs thanks to intelligent pump management
- High measurement reliability through intelligent agitator avoidance
- Connection of maintenance-free, Ex-protected radar and ultrasonic sensors
- Up to 6 relays and galvanically isolated mA outputs
- Easy echo analysis and setting of parameters using free PC software
- Integrated emergency power switchover
- Easy operation in dialog mode using back-lit graphic display
The NivuMaster series transmitters supply connected R- Series and P-Series sensors, process measurement values and indicate readings. NivuMaster transmitters are ideally suitable for simple control tasks in level measurement applications. Flow measurements in open channel using a Venturi flume or Q/h-relations, on any kind of weir or discharge sills are possible without any problems.
NivuMaster is available with wall mount enclosure, as 19"-plugin or with panel mount enclosure.
The few parameters required for measuring can be entered easily on site in dialog mode thanks to the back-lit display and the integrated keypad.
Parameters can be evaluated using the free software “PC Software Suite” and the serial interface of the transmitter.
Type overview
NivuMaster L2 (NMX)
Compact standard model with 2 relays for level and volume measurement.
NivuMaster 5 Relais (NM6)
Extended NivuMaster for measurement of level, volume and quantity as well as for control of pumps and elaborated control tasks.
Typical NivuMaster Applications
- Wastewater: stormwater overflow tanks and storage sewers, clarifiers, pump stations, screening plants, flow measurements, volume measurements in vessels, container monitoring, irrigation facilities
- Drinking water: tank level measurements, water treatment, seawater desalination facilities, level measurements
- Flood protection: stormwater retention tanks, level measurements with remote data transmission, surface waters
- Power generation: cooling water circuits, hydropower plants
Common | |
---|---|
Communication (optional) | Modbus RTU |
Menu languages | English, French, German |
Ex-Approval | ATEX, Zone 0 / 1 |
PC Programming | via RS232 |
Echo processing | intelligent agitator avoidance |
Operation | local operation with key panel |
Display | graphic LCD display
|
Max. humidity | 80 % non-condensing |
Storage temperature | -30 °C to +60 °C |
Operating temperature | -20 °C to +50 °C |
Power consumption | max. 10 W (6 W typical) |
Protection | Wall mount enclosure: IP 65 Panel mount: IP 65 (front), IP 20 (rear) 19“: IP 20
|
Enclosure material: | Polycarbonate, low flammability (UL91) |
Power supply | 115 V AC +5 % / -10 %; 50/60 Hz 230 V AC +5 % / 10 %; 50/60 Hz direct current 18 – 36 V DC
|
Specifications subject to change.
NivuMaster L2 | |
---|---|
Outputs | 2 x relay outputs 1 x mA output |
Inputs | 1 x sensor input |
Enclosure | Wall mount |
Description | Compact standard model with 2 relays for level and volume measurement. |
Part-No. | NMX- |
Specifications subject to change.
NivuMaster 5 Relais | |
---|---|
Outputs | 5 x relay outputs 1 x mA output |
Inputs | 1 x sensor input 1 x 4-20 mA input (optional) |
Enclosure | Wall mount Panel mount 19" plug-in unit |
Description | Extended NivuMaster for measurement of level, volume and quantity as well as for control of pumps and elaborated control tasks. |
Part-No. | NM6- |
Specifications subject to change.
Instruction Manual NivuMaster (NM5+NM6)
Instruction manual for measurement transmitter NivuMaster-Series